Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
J. bras. pneumol ; 39(3): 382-386, jun. 2013. tab, graf
Article in English | LILACS | ID: lil-678257

ABSTRACT

Lung volume recruitment involves deep inflation techniques to achieve maximum insufflation capacity in patients with respiratory muscle weakness, in order to increase peak cough flow, thus helping to maintain airway patency and improve ventilation. One of these techniques is air stacking, in which a manual resuscitator is used in order to inflate the lungs. Although intrathoracic pressures can rise considerably, there have been no reports of respiratory complications due to air stacking. However, reaching maximum insufflation capacity is not recommended in patients with known structural abnormalities of the lungs or chronic obstructive airway disease. We report the case of a 72-year-old woman who had poliomyelitis as a child, developed torsion scoliosis and post-polio syndrome, and had periodic but infrequent asthma attacks. After performing air stacking for 3 years, the patient suddenly developed a pneumothorax, indicating that this technique should be used with caution or not at all in patients with a known pulmonary pathology.


O recrutamento do volume pulmonar envolve técnicas de insuflações pulmonares profundas para se atingir a capacidade de insuflação máxima em pacientes com fraqueza da musculatura respiratória, a fim de aumentar o pico de fluxo da tosse e assim auxiliar a manutenção da patência de vias aéreas e melhorar a ventilação. Uma dessas técnicas é o empilhamento de ar, na qual se utiliza um ressuscitador manual para insuflar os pulmões. Embora as pressões intratorácicas possam aumentar consideravelmente, não há relatos de complicações por empilhamento de ar. Entretanto, atingir a capacidade de insuflação máxima não é recomendado em pacientes com anormalidades na estrutura pulmonar ou doença obstrutiva crônica das vias aéreas. Relatamos o caso de uma paciente de 72 anos que teve poliomielite quando criança, desenvolveu escoliose de torção e síndrome pós-pólio e tinha exacerbações de asma periódicas, mas infrequentes. Após realizar empilhamento de ar por 3 anos, a paciente subitamente desenvolveu pneumotórax, mostrando que essa técnica deve ser utilizada com cuidado ou não ser utilizada por pacientes com patologia pulmonar conhecida.


Subject(s)
Aged , Female , Humans , Barotrauma/etiology , Insufflation/adverse effects , Pneumothorax/etiology , Lung Volume Measurements/methods , Lung/pathology , Positive-Pressure Respiration/methods
2.
Acta cir. bras ; 27(12): 848-854, dez. 2012. graf, tab
Article in English | LILACS | ID: lil-657967

ABSTRACT

PURPOSE: To assess comparatively the inflammatory response that follows CO2 or Ringer's lactate joint capsular distension of horses submitted to experimental arthroscopy METHODS: Each animal was submitted to a bilateral tarsocrural arthroscopy employing gas distention in one joint and fluid distention in the contralateral joint. Synovial fluid was evaluated at 0, six, 12, 24 and 48 hours post-operative. RESULTS: The use of CO2 for arthroscopy causes an acute and mild synovitis alike to the liquid capsular distension, showing similar synovial fluid increase of leukocytes, TP, and TNF-α. Although synovial fluid PGE2 content was higher in joints submitted to CO2 distension, lower levels of hemoglobin and leukocytes oxidative burst after surgery indicates that CO2 arthroscopy decreased intra-articular bleeding and activation of infiltrating leukocytes. CONCLUSIONS: The use of CO2 for arthroscopic examination causes acute and mild synovitis that is similar to the effects caused by the liquid capsular distension. CO2 also seems to decrease intra-articular bleeding and activation of leukocytes.


OBJETIVO: Avaliar comparativamente a resposta inflamatória decorrente da distensão líquida ou gasosa em cavalos submetidos ao exame artroscópico. MÉTODOS: Cada animal foi submetido a uma artroscopia bilateral tarsocrural empregando uma distensão com gás em uma articulação e líquido na articulação contralateral. O líquido sinovial foi avaliado as zero, seis, 12, 24 e 48 horas do pós-operatório. RESULTADOS: A utilização de CO2 para a artroscopia provoca uma sinovite aguda e leve tal como a distensão capsular por líquido, mostrando um aumento similar de leucócitos, TP (proteína total) e TNF-a. Embora no líquido sinovial a quantidade de PGE2 tenha sido maior nas articulações submetidas à distensão por CO2, níveis mais baixos de hemoglobina e explosão oxidativa de leucócitos após a cirurgia indica que a artroscopia com CO2 diminuiu o sangramento intra-articular e ativação de leucócitos. CONCLUSÕES: A utilização de CO2 para exame artroscópico provoca uma sinovite aguda e leve que são semelhantes aos efeitos causados pela distensão capsular por líquido. O CO2 também parece diminuir o sangramento intra-articular e a ativação de leucócitos.


Subject(s)
Animals , Female , Male , Arthroscopy/veterinary , Insufflation/veterinary , Joints/surgery , Arthroscopy/methods , Carbon Dioxide/administration & dosage , Flow Cytometry , Horses , Injections, Intra-Articular/veterinary , Insufflation/adverse effects , Insufflation/methods , Synovial Fluid , Synovitis/etiology
3.
Yonsei Medical Journal ; : 459-466, 2012.
Article in English | WPRIM | ID: wpr-58141

ABSTRACT

Clinically significant carbon dioxide embolism is a rare but potentially fatal complication of anesthesia administered during laparoscopic surgery. Its most common cause is inadvertent injection of carbon dioxide into a large vein, artery or solid organ. This error usually occurs during or shortly after insufflation of carbon dioxide into the body cavity, but may result from direct intravascular insufflation of carbon dioxide during surgery. Clinical presentation of carbon dioxide embolism ranges from asymptomatic to neurologic injury, cardiovascular collapse or even death, which is dependent on the rate and volume of carbon dioxide entrapment and the patient's condition. We reviewed extensive literature regarding carbon dioxide embolism in detail and set out to describe the complication from background to treatment. We hope that the present work will improve our understanding of carbon dioxide embolism during laparoscopic surgery.


Subject(s)
Humans , Carbon Dioxide/adverse effects , Embolism, Air/diagnosis , Insufflation/adverse effects , Laparoscopy/adverse effects
4.
Acta cir. bras ; 23(1): 48-54, Jan.-Feb. 2008. graf
Article in English | LILACS | ID: lil-474140

ABSTRACT

PURPOSE: To asses the dissemination of bacteria labeled with technetium-99m (99mTc) from peritoneal cavity after different surgical procedures. METHODS: Bacteria of the Escherichia coli species labeled with 99mTc were used in a concentration of 10(8) units of colony-makers for ml (UFC/ml) and 1ml was inoculated through intra-peritoneal via. Forty-eight rats were divided into four groups: control, laparotomy, pneumoperitoneum with 10mmHg and pneumoperitoneum with 20mmHg of CO2. Procedures were performed 20 min after injection of the inoculum and lasted 30 min. Animals were sacrificed after six hours (Group 1) and 24 hours (Group 2). Samples of blood, liver and spleen were collected for radioactivity counting. RESULTS: After six hours, indirect detection of the bacteria in different organs was uniform in all groups. After 24 hours, a larger detection of technetium was observed in the livers of animals of the group insufflated with 20mmHg of CO2, when compared with those of control group (p<0.01). The other groups did not present statistically significant variations. CONCLUSIONS: The use of a higher intra-abdominal pressure was associated with a higher bacterial dissemination to the liver. The application of lower intra-abdominal pressures may be associated with a lower dissemination of the infectious status during laparoscopic approach of peritonitis status.


OBJETIVO: Avaliar a disseminação de bactérias marcadas com tecnécio-99m (99mTc) a partir da cavidade peritoneal após diferentes procedimentos cirúrgicos. MÉTODOS: Foram utilizadas bactérias da espécie Escherichia coli marcadas com 99mTc em uma concentração de10(8) unidades formadoras de colônia por ml (UFC/ml) sendo inoculado 1ml por via intra-peritoneal. Quarenta e oito ratos foram divididos em quatro grupos: controle, laparotomia, pneumoperitôneo com 10 mmHg e pneumoperitôneo com 20 mmHg de CO2. Os procedimentos foram realizados 20 minutos após a injeção do inóculo e duraram 30 minutos. Os animais foram sacrificados após seis horas (grupo 1) e 24 horas (grupo 2). Foram coletadas amostras de sangue, fígado e baço para contagem radioativa. RESULTADOS: Após seis horas, a detecção indireta das bactérias nos diferentes órgãos foi uniforme em todos os grupos. Após 24 horas, observou-se uma maior detecção de tecnécio nos fígados dos animais do grupo insuflado com 20 mmHg de CO2, quando comparados aos do grupo controle (p<0,01). Os outros grupos não apresentaram variações estatisticamente significativas. CONCLUSÕES: A utilização de pressões intra-abdominais mais elevadas associou-se a uma maior disseminação bacteriana para o fígado. A utilização de pressões intra-abdominais menos elevadas na abordagem da peritonite pode estar associada a uma menor disseminação do quadro infeccioso.


Subject(s)
Animals , Male , Rats , Escherichia coli Infections , Escherichia coli/growth & development , Peritonitis/surgery , Pneumoperitoneum, Artificial/adverse effects , Sepsis , Colony Count, Microbial , Disease Models, Animal , Escherichia coli Infections/microbiology , Escherichia coli/drug effects , Insufflation/adverse effects , Laparoscopy/adverse effects , Laparotomy/adverse effects , Liver/microbiology , Liver/radiation effects , Peritoneal Cavity/microbiology , Peritonitis/microbiology , Peritonitis , Pneumoperitoneum, Artificial/methods , Rats, Wistar , Sepsis/microbiology , Spleen/microbiology , Spleen/radiation effects , Technetium
5.
Rev. bras. anestesiol ; 55(1): 87-89, jan.-fev. 2005.
Article in Portuguese, English | LILACS | ID: lil-393575

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: A embolia venosa por CO2 durante cirurgias laparoscópicas é uma complicação rara, porém fatal na maioria dos casos. O objetivo deste relato é descrever um caso não fatal de embolia venosa por CO2 durante cirurgia laparoscópica. RELATO DO CASO: Paciente hipertensa foi submetida à anestesia geral para laparoscopia para exploração de colédoco. Após 150 minutos de pneumoperitôneo, a paciente evoluiu com taquicardia e hipotensão refratária ao uso de vasopressor. A gasometria arterial revelou grande diferença entre a pCO2 e a P ET CO2. Frente à hipótese de embolia gasosa, foi desinsuflado o pneumoperitôneo, e a cirurgia terminada pela técnica convencional. A paciente evoluiu com melhora do quadro hemodinâmico, sendo extubada ao término da cirurgia e encaminhada para sala de recuperação pós-anestésica (SRPA). CONCLUSÕES: O diagnóstico precoce e o tratamento imediato foram fundamentais na boa evolução do caso descrito.


Subject(s)
Female , Aged , Humans , Carbon Dioxide , Cholecystectomy, Laparoscopic , Embolism, Air/diagnosis , Embolism, Air/etiology , Intraoperative Complications , Insufflation/adverse effects
6.
Rev. mex. anestesiol ; 21(2): 87-91, abr.-jun. 1998.
Article in Spanish | LILACS | ID: lil-248370

ABSTRACT

Se evaluó la frecuencia con que se rebasa la presión arterial de perfusión de 25 cm H2O al insuflar el globo del tubo endotraqueal. Establecimos la correlación entre presión de inflado y presencia de disfonía o dolor de garganta. Se estudió tubo endotraqueal, marca, díametro interno, presión y volumen utilizados a la intubación y previo a su extubación, se utilizó un instrumento P-V Gauge, se evaluó disfonía y dolor de garganta con escala visual análoga. Análisis estadístico realizado en frecuencia, Chi cuadrada, media, desviación estándar, hipótesis t pareada y r de Pearson. 25 pacientes, 12 mujeres y 13 hombres, con valores de media siguientes: 48.92 años, pero 63.08 kg, sondas con diámetro interno 7.96 mm, volumen inicial 5.18 ml de aire, presión mayor de 25 en 68 por ciento de pacientes y media 42.52 cm de H2O, antes de extubar: volumen de 5.54 ml y presión mayor de 25 en 68 por ciento de pacientes y media 42,20 cm 42.20 cm de H2O. La intubación duró 133.80 minutos como media. Hubo disfonía en 56 por ciento de pacientes, dolor de garganta en 52 por ciento. Obtuvimos significancia estadística entre presión aumentada del globo del tubo endotraqueal y presencia de disfonía y/o dolor de garganta


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Pharyngitis/etiology , Voice Disorders/etiology , Larynx/injuries , Insufflation/adverse effects , Intubation, Intratracheal
8.
Article in English | IMSEAR | ID: sea-41468

ABSTRACT

Although laparoscopic cholecystectomy has several advantages over the traditional open cholecystectomy, it may however cause some adverse cardiovascular and respiratory effects associated with intraperitoneal insufflation of CO2. It is, therefore, recommended that appropriate hemodynamic and respiratory monitorings should be used routinely in order to prevent deleterious complications, especially in high risk patients.


Subject(s)
Adult , Aged , Carbon Dioxide , Cardiovascular Diseases/epidemiology , Cholecystectomy, Laparoscopic/adverse effects , Female , Humans , Insufflation/adverse effects , Intraoperative Complications , Male , Middle Aged , Respiration Disorders/epidemiology , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL